Repeatability of RRate measurements in children during triage in two Ugandan hospitalsLink copied to clipboard!
-
- Description:
Background: Pneumonia is the leading cause of death in children globally. In low- and middle-income countries the diagnosis of pneumonia relies heavily on an accurate assessment of respiratory rate, which can be unreliable in nurses and clinicians with less advanced training. In order to inform more accurate measurements, we investigate the repeatability of the RRate app used by nurses in district hospitals in Uganda.
Methods: This planned secondary analysis included 3679 children aged 0-5 years. The dataset had two sequential measurements of respiratory rate using the RRate app. We measured the agreement between respiratory rate observations and clustering around fixed thresholds defined by WHO for fast breathing, which are 60 breaths per minute (bpm) for under two months (Age-1), 50 bpm for two to 12 months (Age-2), and 40 bpm for 12.1 to 60 months (Age-3). We then assessed the repeatability of the paired measurements using the Intraclass Correlation Coefficient (ICC).
Results: The respiratory rate measurement took less than 15 seconds for 7,277 (98.9%) of the measurements. Despite respiratory rates clustering around the WHO fast-breathing thresholds, the breathing classification based on the thresholds was changed in only 12.6% of children. The mean (SD) respiratory rate by age group was 60 (13.1) bpm for Age-1, 49 (11.9) bpm for Age-2, and 38 (10.1) for Age-3, and the bias (Limits of Agreements) were 0.3 (-10.8 – 11.3), 0.4 (-8.5 – 9.3), and 0.1 (-6.8, 7.0) for Age-1, Age-2, and Age-3 respectively. Most importantly, the repeatability of the two respiratory rate measurements for the 3,679 children was high, with an ICC value (95% CI) of 0.95 (0.94 – 0.95).
Discussion: The RRate measurements were both efficient and repeatable. The simplicity, repeatability, and efficiency of the RRate app used by healthcare workers in LMICs supports more widespread adoption for clinical use.
NOTE for restricted files: If you are not yet a CoLab member, please complete our membership application survey to gain access to restricted files within 2 business days.
Some files may remain restricted to CoLab members. These files are deemed more sensitive by the file owner and are meant to be shared on a case-by-case basis. Please contact the CoLab coordinator at sepsiscolab@bcchr.ca or visit our website.-
- Auteur(s) :
- Asdo, Ahmad, Mawji, AlishahUniversity of British Columbia, Omara, IsaacUniversity of British Columbia, Aye Ishebukara, Ivan Aine, Komugisha, ClareGulu Regional Referral Hospital, Novakowski, StefanieWalimu, Pillay, YashodaniUniversity of British Columbia, Wiens, Matthew OUniversity of British Columbia, Akech, Samuel, Oyella, FlorenceKEMRI-Wellcome Trust Research Programme, Tagoola, AbnerGulu Regional Referral Hospital, Kissoon, NiranjanJinja Regional Referral Hospital, Ansermino, J MarkUniversity of British Columbiaet Dunsmuir, DustinUniversity of British Columbia
- Contributor(s):
- Huxford, Charly
-
- Dépôt source:
- UBC Dataverse
- Series:
- Pediatric Sepsis Data CoLab // Clinical studies // Smart Triage // Smart Triage - Manuscripts
- Éditeur(s):
- Borealis
-
- Accès:
- Restricted
-
- License:
- CC BY-NC-SA 4.0
-
- URL:
- https://doi.org/10.5683/SP3/XO7BVV
-
- Date de publication:
- 2024-03-14
-
- Sujets (en):
-
- Mots-clés (en):
-
- Identificateur:
- https://doi.org/10.5683/SP3/XO7BVV
Information géospatiale
Il n’y a aucune information géospatiale pour cette notice.
Sélectionner le ou les éléments géospatiaux à afficher sur la carte :
Notez : Jusqu’à 1000 caractéristiques pour chaque fichier sont affichées.
Référence bibliographique
-
- Citation selon les normes APA:
-
Repeatability of RRate measurements in children during triage in two Ugandan hospitals. (2024). [Data set]. UBC Dataverse. https://doi.org/10.5683/SP3/XO7BVVRéférence copiée dans le presse-papier
-
- Exporter vers le gestionnaire de références bibliographiques :
-